Abstract
A dc transport current was applied to the strands of a Roebel cable at 77 K in liquid nitrogen bath. The inter-strand contact resistance was measured. It was modified either by applying a pressure on the cable at 77 K in liquid nitrogen bath or using different soldering patterns between the strands of the cable. Magnetization ac losses were measured in frequency range 50 – 200 Hz in applied magnetic field 4 – 70 mT perpendicular to the broader face of the cable to test the inter-strand contact resistance effect. High stability and very low level of coupling losses was observed in the cables even with the lowest interstrand resistances.
Description
Keywords
current sharing, roebel cable, stability
Citation
Published version: IEEE Transactions on Applied Superconductivity (Volume: 24, Issue: 3, June 2014) Article Sequence Number: 6600505. https://doi.org/10.1109/TASC.2013.2283472