Show simple item record

dc.creatorMills, Andrew A.en_US
dc.creatorMohr, Christianen_US
dc.creatorJiang, Jieen_US
dc.creatorGatti, Davideen_US
dc.creatorMarangoni, Marcoen_US
dc.creatorDe Vizia, Maria Domenicaen_US
dc.creatorGianfrani, Livioen_US
dc.creatorHartl, Ingmaren_US
dc.creatorFermann, Martinen_US
dc.date.accessioned2013-07-16T21:39:58Z
dc.date.available2013-07-16T21:39:58Z
dc.date.issued2013en_US
dc.identifier2013-TF-13en_US
dc.identifier.urihttp://hdl.handle.net/1811/55374
dc.descriptionAuthor Institution: IMRA America, Ann Arbor, MI; Dipartimento di Fisica del Politecnico di Milano, Milano, Italy; Seconda Universita Di Napoli, Caserta, Italy; Deutsches Eleketronen-Synchrotron, Hamburg, Germany; IMRA America, Ann Arbor, MIen_US
dc.description.abstractThe thermodynamic temperature of a gaseous medium at thermodynamic equilibrium can be extracted from molecular spectra by examining: the relative intensities of rotational structures, the relative intensity of vibrational satellites, or the Doppler width of individual rovibrational lines. Of these methods, Doppler broadening thermometry (DBT), measuring the Doppler width of a single, well-isolated absorption profile, represents a primary method providing the most accurate optical determinations. DBT requires highly precise, accurate and repeatable frequency scanning of a narrow-linewidth probe laser around a given center frequency. This requirement often calls for complicated sideband-based approaches or frequency-locking techniques. We describe here an elegant implementation of Doppler broadening thermometry in which a room-temperature continuous-wave quantum cascade laser at 9.07 $\mu$m is coherently phase-locked to a thulium frequency comb centered at 2 $\mu$m. Repeated tuning of the repetition-rate enables wide and highly accurate frequency scans throughout multiple rovibrational lines of ammonia. Hence, the thermodynamic temperature is retrieved from a manifold of profiles, rather than from a single, isolated line, taking advantage of the simple scaling law that relates Doppler width and line-center frequency. This is realized, regardless of the complexity of the adopted lineshape model, by implementing a multiple-line fitting procedure with some relevant physical constraints. The precision attained for the retrieved gas temperature, even in the absence of an accurate control of the thermodynamic conditions of the ammonia sample, is as high as 50 ppm, even from an analysis of a restricted number of spectra ($\sim$100), acquired at different gas pressures. This represents a particularly relevant result as compared to previous DBT based upon Doppler-width retrievals from an isolated spectral line.en_US
dc.language.isoenen_US
dc.publisherOhio State Universityen_US
dc.titleCOMB-ASSISTED QCL DOPPLER-BROADENED THERMOMETRY IN NH$_3$ SAMPLESen_US
dc.typeArticleen_US


Files in this item

Thumbnail

Items in Knowledge Bank are protected by copyright, with all rights reserved, unless otherwise indicated.

This item appears in the following Collection(s)

Show simple item record