Show simple item record

dc.creatorHolzwarth, Ronalden_US
dc.creatorBernhardt, Birgittaen_US
dc.creatorOzawa, Akiraen_US
dc.creatorUdem, Thomasen_US
dc.creatorHansch, Theodor W.en_US
dc.creatorJacquet, Patricken_US
dc.creatorJacquey, Marionen_US
dc.creatorGuelachvili, Guyen_US
dc.creatorKobayashi, Yoheien_US
dc.creatorPicque, Nathalieen_US
dc.date.accessioned2010-07-12T14:05:09Z
dc.date.available2010-07-12T14:05:09Z
dc.date.issued2010en_US
dc.identifier2010-RD-01en_US
dc.identifier.urihttp://hdl.handle.net/1811/46194
dc.descriptionAuthor Institution: Max-Planck-Institute for Quantum Optics, 81748 Garching, Germany and Menlo Systems GmbH, 82152 Martinsried, Germany; Max-Planck-Institute for Quantum Optics, 81748 Garching, Germany; Laboratoire de Photophysique Moleculaire, CNRS, Batiment 350, Universite Paris-Sud, 91405 Orsay, France; Institute for Solid State Physics, University of Tokyo, 5-1-5 Kashiwanoha, Kashiwa, Chiba 277-8581, Japan; Max-Planck-Institute for Quantum Optics, 81748 Garching, Germany and Laboratoire de Photophysique Moleculaire, CNRS, Batiment 350, Universite Paris-Sud, 91405 Orsay, Franceen_US
dc.description.abstractClassical FTIRs handle the task of massively parallel spectroscopic probing by interferometric detection. In contrast a frequency comb Fourier transform spectrometer (FC-FTS) retains the principle of combining two interferometer beams but uses two inputs from two independent sources. Thus we can offset their frequencies to facilitate multifrequency heterodyne signal processing. The advantages of this spectrometer compared with the classical FTIR include ease of operation (no cumbersome moving delay lines), speed of acquisition (18 $\mu$s demonstrated), collimated long-distance propagation, possibly diffraction-limited microscopic probing, and mid infrared as well as THz operation if necessary. In a recent proof of principle experiment we have dramatically improved the sensitivity by the implementation of an enhancement cavity around the probing volume nderline{\textbf{4}} (55), January 2010}. We recorded, within 18 $\mu$s, spectra of the ammonia 1.0 $\mu$m overtone bands comprising 1500 spectral elements and spanning 20 nm with 4.5 GHz resolution and a noise-equivalent-absorption at one-second-averaging of 1 $10^{-10} $cm$^{-1}$Hz$^{-1/2}$, thus opening a route to time-resolved spectroscopy of rapidly-evolving single-events. Since FC-FTS only needs one detector that is easily available in practically all spectral regions, it can be envisioned that cavity-enhanced FC-FTS will assume a position of dominance for the measurements of real-time ultra-sensitive spectra in the molecular fingerprint region.en_US
dc.language.isoenen_US
dc.publisherOhio State Universityen_US
dc.titleBROADBAND SPECTROSCOPY WITH DUAL COMBS AND CAVITY ENHANCEMENTen_US
dc.typeArticleen_US


Files in this item

Thumbnail

Items in Knowledge Bank are protected by copyright, with all rights reserved, unless otherwise indicated.

This item appears in the following Collection(s)

Show simple item record