Show simple item record

dc.creatorSong, Yangen_US
dc.creatorEvans, M.en_US
dc.creatorNg, C. Y.en_US
dc.creatorJarvis, G.en_US
dc.date.accessioned2006-06-15T19:19:37Z
dc.date.available2006-06-15T19:19:37Z
dc.date.issued1999en_US
dc.identifier1999-TA-07en_US
dc.identifier.urihttp://hdl.handle.net/1811/19425
dc.description$^{a}$ C.Y. Ng, in ``Photoionization and Photodelachment'', edited by C.Y. Ng (World Scientific, Singapore, 1999) Adv. Ser Phys. Chem., Vol. 10A, in press. $^{b}$ G.K. Jarvis, Y. Song, and C.Y. Ng, Rev. Sci. Instrum., submitted. $^{c}$ G.K. Jarvis, Y. Song, and C.Y. Ng, J. Chem. Phys., submitted.en_US
dc.descriptionAuthor Institution: Ames Laboratory and Department of Chemistry, Iowa State Univ.; Chemical Science Division, Lawrence Berkeley National Lab.en_US
dc.description.abstractWe have demonstrated a novel experimental scheme for pulsed field ionization photoelectron (PFI-PE) measurements using the monochromatized multi-bunch undulator synchrotron source at the Chemical Dynamics Beamline of the Advanced Light Source $(ALS).^{1}$ In this technique, high-n $(n \geq 100)$ Rydberg states are field ionized by a small electric field applied in the dark gap of a synchrotron ring period. Using an electron spectrometer equipped with a steradiancy analyzer and a hemispherical electron energy analyzer, we have shown that PFI-PEs can be detected with little prompt electron background for a delay of only 8 ns with respect to the beginning of the dark gap. This scheme overcomes the requirement for a delay in the $\mu s$ range in laser PFI-PE studies. The greatest advantage of synchrotron radiation is the ease of tunability in the full vacuum ultraviolet (VUV) range of 6-30 eV, meaning that vibronic photoelectron progressions arising from valence shell ionization of all molecular species can be studied in their entirety with rotational resolution. Recently, we have further developed an efficient electron time-of-flight (TOF) selection scheme for PFI-PE $studies.^{2}$ By employing a simple TOF spectrometer, we show that PFI-PEs produced by the PFI in the dark gap can be cleanly separated from prompt electrons. A near complete suppression of prompt electrons was achieved by gating the PFI-PE TOF peak. We have demonstrated instrumental resolution of $1.0 cm^{-1}$ (FWHM), which is close to the best [$0.8 cm^{-1}$ (FWHM)] achieved in VUV laser PFI-PE experiments. Using these new experimental methods, we have obtained rotationally resolved vibrational progressions for many diatomic and triatomic molecules close to their dissociation $limits.^{1}$ The analyses of PFI-PE bands for highly vibrationally excited diatomic ions, $^{3}O^{+}_{2}, NO^{+}$, and $CO^{+}$ will be presented.en_US
dc.format.extent200929 bytes
dc.format.mimetypeimage/jpeg
dc.language.isoEnglishen_US
dc.publisherOhio State Universityen_US
dc.titleADVANCES IN PHOTOELECTRON SPECTROSCOPY USING THIRD GENERATION UNDULATOR SYNCHROTRON RADIATIONen_US
dc.typearticleen_US


Files in this item

Thumbnail

Items in Knowledge Bank are protected by copyright, with all rights reserved, unless otherwise indicated.

This item appears in the following Collection(s)

Show simple item record