Show simple item record

dc.creatorMartin, J. P.en_US
dc.creatorSoufiani, A.en_US
dc.creatorBrenez, L.en_US
dc.creatorRolon, J.-C.en_US
dc.date.accessioned2006-06-15T19:13:55Z
dc.date.available2006-06-15T19:13:55Z
dc.date.issued1999en_US
dc.identifier1999-MF-06en_US
dc.identifier.urihttp://hdl.handle.net/1811/19244
dc.descriptionAuthor Institution: Laboratoire EM2C, UPR 288 du CNRS, Ecole Centrale Parisen_US
dc.description.abstractWe compare in this study different data reduction techniques to measure the local temperature and $H_{2}O, CO_{2}$ and CO concentrations in a two-dimensional burner. The spectra are recorded with a $0.02 cm^{-1}$ spectral resolution in the $1700-4300 cm^{-1}$ range which contains significant emission from the above cited molecules. The emission spectra are calibrated using a blackbody which also serves to correct the absorption by residual air in the optical path (about 20 mm.atm). In the first technique, the calibrated high resolution spectra are downgraded to a $25 cm^{-1}$ resolution and a non linear least-square adjustment is used to fit the experimental spectra to theoretical ones calculated from the EM2C high temperature approximate spectroscopic data bases. The unknown parameters in this adjustment are both the temperature and species concentrations. This method yields reliable temperature and $H_{2}O$ and $CO_{2}$ concentrations as compared to other conventional techniques, but not accurate CO concentrations. In the second technique, the ratio of two CO line intensities is used to determine the temperature. We choose the 1-OP(27) and 2-1P(27) to avoid uncertainties due to line shapes. This technique gives good agreement with the previous one but is limited to regions where CO concentration is high enough (more than 0.002). CO concentration is determined from the center-line intensity value using several lines. The uncertainty in this last measurement is about 5 to 10\% due mainly to the uncertainty in CO collisional line widths at high temperature. Nevertheless, the detection limit is evaluated to $10^{-3}$ mole fraction.en_US
dc.format.extent153168 bytes
dc.format.mimetypeimage/jpeg
dc.language.isoEnglishen_US
dc.publisherOhio State Universityen_US
dc.titleFTIR FLAME EMISSION SPECTROSCOPY FOR TEMPERATURE AND SPECIES CONCENTRATION MEASUREMENTSen_US
dc.typearticleen_US


Files in this item

Thumbnail

Items in Knowledge Bank are protected by copyright, with all rights reserved, unless otherwise indicated.

This item appears in the following Collection(s)

Show simple item record