Show simple item record

dc.creatorShaw, B. M.en_US
dc.creatorLovell, R. J.en_US
dc.date.accessioned2006-06-15T16:48:58Z
dc.date.available2006-06-15T16:48:58Z
dc.date.issued1968en_US
dc.identifier1968-Z-6en_US
dc.identifier.urihttp://hdl.handle.net/1811/15647
dc.descriptionThis research was supported by the Office of Aerospace Research, U.S.A.F. Contract Nos. AF19(604)-7980, AF19(628)-4323 and by N.A.S.A. Research Grant NsG-539. Present address of B.M. Shaw: Fiber Industries Inc., Charlotte, N.C.en_US
dc.descriptionAuthor Institution: Department of Physics and Astronomy, The University of Tennesseeen_US
dc.description.abstractA new approach to the application of the equivalent width method was developed. In previous experiments the line intensities had been determined from a knowledge of $x_{2}/x_{1}$, where x is the parameter defined in the Landenburg-Reiche equation, and 1 and 2 refer to the different experimental conditions required for the determination. The methods used to accomplish this had been to use cells of different lengths, or to use gas mixtures of different compositions by varying the pressures of the absorber and foreign gas. Neither of these methods give rise to accurate values for the intensity. In this work the intensities were obtained from a knowledge of the maximum absorption coefficients for the case of pure HF, and the assumption that the intensity of a special line depended only on the amount of the absorber present, and was independent of the pressure of the broadening gas. The values obtained for the half-widths agreed closely with those obtained by using the line shape method. Thus experimental evidence was obtained which supports the assumption that the line intensity is dependent only on the amount of the absorber present. The line shapes were investigated for the lines which could be slit corrected. It was found that the Lorentz exponent changed from the value of 2.0 for the narrowest lines to a value of approximately 1.85 for the widest lines investigated. The deviations from Lorentz shape, in all cases, began where the half absorption half width was approximately 0.75 wavenumbers. The directly measured intensities of those lines which could be slit corrected agreed closely with the results from the equivalent width method, giving even stronger support to the assumption that the line intensity is dependent only on the amo*** *** the absorber present.en_US
dc.format.extent244943 bytes
dc.format.mimetypeimage/jpeg
dc.language.isoEnglishen_US
dc.publisherOhio State Universityen_US
dc.titleFOREIGN GAS BROADENING OF HF LINES BY $CO_{2}$en_US
dc.typearticleen_US


Files in this item

Thumbnail

Items in Knowledge Bank are protected by copyright, with all rights reserved, unless otherwise indicated.

This item appears in the following Collection(s)

Show simple item record