OSU Navigation Bar

The Ohio State University University Libraries Knowledge Bank

The Knowledge Bank is scheduled for regular maintenance on Sunday, April 20th, 8:00 am to 12:00 pm EDT. During this time users will not be able to register, login, or submit content.

NOAA HIGH RESOLUTION VACUUM IR SPECTROMETER

Please use this identifier to cite or link to this item: http://hdl.handle.net/1811/9661

Show simple item record

Files Size Format View
1976-RA-02.jpg 171.3Kb JPEG image Thumbnail of NOAA HIGH RESOLUTION VACUUM IR SPECTROMETER

dc.creator Fridovich, B. en_US
dc.creator Champion, E. E. en_US
dc.creator Smith, G. R. en_US
dc.date.accessioned 2006-06-15T13:45:45Z
dc.date.available 2006-06-15T13:45:45Z
dc.date.issued 1976 en_US
dc.identifier 1976-RA-2 en_US
dc.identifier.uri http://hdl.handle.net/1811/9661
dc.description Author Institution: National Oceanic and Atmospheric Administration, National Environmental Satellite Service en_US
dc.description.abstract This 3.5 meter vacuum grating spectrometer is of a classical double passed Czerny-Turner configuration and is equipped with a $16^{\prime\prime} \times 8^{\prime\prime} (40 cm \times 20 cm)$ 31.6 grooves/mm Harrison-ruled Bausch and Lomb replica echelle. The entire optical path, except for a 2 cm purged path in front of the detector may be evacuated. A 4 meter stainless steel White-type multipath cell is provided for gas absorption measurements. Data can be simultaneously acquired in analog and digital form. The digital system is controlled by PDP-8/E minicomputer. Outputs go to magnetic tape and digital plotter. At present, rudimentary computations may be done on-line, but final processing is accomplished at the NOAA computer facility. Grating position is measured by an optical 10 bit shaft encoder coupled directly to the precision to the precision lead screw which moves the grating arm. Interesting technical features such as vibration isolation, source operation to eliminate CO absorption lines, rolling mount for the multipath cell, etc., which facilitate the day to day operation have been incorporated. Computer programs for deconvolution and line center location are either available or being put into operational form. The main interest of NOAA is the determination of line and band strengths, and line widths and shapes for molecular spectra of atmospheric interest. In the adjacent laboratory, a newly acquired tunable diode laser is being used to study the 15 $\mu_{m} ~CO_{2}$ band in support of NOAA activities in atmospheric temperature sounding from satellites. en_US
dc.format.extent 175506 bytes
dc.format.mimetype image/jpeg
dc.language.iso English en_US
dc.title NOAA HIGH RESOLUTION VACUUM IR SPECTROMETER en_US
dc.type article en_US