OSU Navigation Bar

The Ohio State University University Libraries Knowledge Bank

The Knowledge Bank is scheduled for regular maintenance on Sunday, April 20th, 8:00 am to 12:00 pm EDT. During this time users will not be able to register, login, or submit content.

T2 quantification for improved detection of myocardial edema

Please use this identifier to cite or link to this item: http://hdl.handle.net/1811/45128

Show full item record

Files Size Format View
1532-429X-11-56.pdf 1.089Mb PDF View/Open

Title: T2 quantification for improved detection of myocardial edema
Creators: Giri, Shivraman; Chung, Yiu C.; Merchant, Ali; Mihai, Georgeta; Rajagopalan, Sanjay; Raman, Subha; Simonetti, Orlando
Issue Date: 2009-12-30
Citation: Giri, Shivraman, Chung, Yiu C., Merchant, Ali, Mihai, Georgeta, Rajagopalan, Sanjay, Raman, Subha, Simonetti, Orlando. "T2 quantification for improved detection of myocardial edema," Journal of Cardiovascular Magnetic Resonance v11 (December, 2009), pp. 56-
DOI: 10.1186/1532-429X-11-56
Abstract: BACKGROUND:T2-Weighted (T2W) magnetic resonance imaging (MRI) pulse sequences have been used to detect edema in patients with acute myocardial infarction and differentiate acute from chronic infarction. T2W sequences have suffered from several problems including (i) signal intensity variability caused by phased array coils, (ii) high signal from slow moving ventricular chamber blood that can mimic and mask elevated T2 in sub-endocardial myocardium, (iii) motion artifacts, and (iv) the subjective nature of T2W image interpretation. In this work we demonstrate the advantages of a quantitative T2 mapping technique to accurately and reliably detect regions of edematous myocardial tissue without the limitations of qualitative T2W imaging.METHODS:Methods of T2 mapping were evaluated on phantoms; the best of these protocols was then optimized for in vivo imaging. The optimized protocol was used to study the spatial, view-dependent, and inter-subject variability and motion sensitivity in healthy subjects. Using the insights gained from this, the utility of T2 mapping was demonstrated in a porcine model of acute myocardial infarction (AMI) and in three patients with AMI.RESULTS:T2-prepared SSFP demonstrated greater accuracy in estimating the T2 of phantoms than multi-echo turbo spin echo. The T2 of human myocardium was found to be 52.18 +/- 3.4 ms (range: 48.96 ms to 55.67 ms), with variability between subjects unrelated to heart rate. Unlike T2W images, T2 maps did not show any signal variation due to the variable sensitivity of phased array coils and were insensitive to cardiac motion. In the three pigs and three patients with AMI, the T2 of the infarcted region was significantly higher than that of remote myocardium. CONCLUSION:Quantitative T2 mapping addresses the well-known problems associated with T2W imaging of the heart and offers the potential for increased accuracy in the detection of myocardial edema.
ISSN: 1532-429X
URI: http://hdl.handle.net/1811/45128
Bookmark and Share
Attribution 3.0 Unported This item is licensed under a Creative Commons License:
Attribution 3.0 Unported