OSU Navigation Bar

The Ohio State University University Libraries Knowledge Bank

QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS

Please use this identifier to cite or link to this item: http://hdl.handle.net/1811/31540

Show full item record

Files Size Format View
abstract.gif 17.62Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
silicagel surface area.ppt 662Kb Microsoft PowerPoint View/Open
Slide1.GIF 7.515Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide2.GIF 6.769Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide3.GIF 10.92Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide4.GIF 65.65Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide5.GIF 12.43Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide6.GIF 10.53Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide7.GIF 10.77Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide8.GIF 12.44Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide9.GIF 42.22Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide10.GIF 9.633Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide11.GIF 11.72Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide12.GIF 108.0Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide13.GIF 9.014Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide14.GIF 30.76Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide15.GIF 42.52Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide16.GIF 54.51Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide17.GIF 52.5Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide18.GIF 46.98Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide19.GIF 6.895Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Slide20.GIF 11.70Kb GIF image Thumbnail of QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS

Title: QUANTITATIVE DETERMINATION OF SURFACE AREA OF SILICA GEL PARTICLES BY NEAR INFRARED SPECTROSCOPY AND CHEMOMETRICS
Creators: Christy, Alfred A.
Issue Date: 2007
Abstract: Surface area of silicagel particles has been determined by partial least squares calibration of the near infrared profiles of silica gel particles against BET (Brunauer, Emmet and Teller method) surface area. Two sets of silica samples were prepared in the range 300-600 m$^2$/g and 200-750 m$^2$/g from altogether six silica gel samples with quantitatively determined BET surface areas. The two sets contained 35 and 30 mixtures respectively. They were prepared by mixing different quantities of the silica gel samples so that the resulting mixtures gave gradual increase in surface areas. The Near infrared spectra of the mixtures were then measured in the region 4000-11000 cm$^{-1}$ and the second derivated spectral profiles were calibrated against the respective calculated surface areas of the mixtures. The calibration model was then used to predict the surface area of unknown silica gel samples. The model established with the first set predicted the surface area within an error limit of $\pm$5\%. The model established with second set of samples predicted the surface area with an error limit of $\pm$8\%.
URI: http://hdl.handle.net/1811/31540
Other Identifiers: 2007-TC-12