OSU Navigation Bar

The Ohio State University University Libraries Knowledge Bank

CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION

Please use this identifier to cite or link to this item: http://hdl.handle.net/1811/31427

Show full item record

Files Size Format View
abstract.gif 17.94Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
OSU HEB 2007.ppt 4.797Mb Microsoft PowerPoint View/Open
Slide1.GIF 7.022Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide2.GIF 57.99Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide3.GIF 16.29Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide4.GIF 45.37Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide5.GIF 25.26Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide6.GIF 78.65Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide7.GIF 5.812Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide8.GIF 6.243Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide9.GIF 27.69Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide10.GIF 30.97Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide11.GIF 7.577Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide12.GIF 6.947Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Slide13.GIF 23.79Kb GIF image Thumbnail of CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION

Title: CHARACTERIZATION OF A HEB DETECTOR FOR THz RADIATION
Creators: Kelley, Matthew J.; Braakman, Rogier; Blake, Geoffrey A.; Santavicca, Daniel F.; Reese, Matthew O.; Prober, Daniel E.
Issue Date: 2007
Abstract: We have begun to characterize the response of an antenna coupled niobium hot electron bolometer (HEB) at 4.2K. Specifically, the responsivity was measured to be 1 x 10$^4$ V/W at 4.2 K. Such technology couples the excellent responsivity of thermal bolometers with $<10$ nanosecond response times and with the ability to function while observing a room temperature background without becoming saturated. The detector is both faster and more sensitive than any known commercially available detector. We plan to use the devices as both direct detectors for THz radiation as well as heterodyne front ends for our proposed Fourier Transform THz Spectrometer. This research is motivated by the impending data from Herschel and SOFIA and the lack of laboratory spectra for many of the complex molecules that are expected to have intense torsional modes in the THz region of the spectrum.
URI: http://hdl.handle.net/1811/31427