OSU Navigation Bar

The Ohio State University University Libraries Knowledge Bank

The Knowledge Bank is scheduled for regular maintenance on Sunday, April 20th, 8:00 am to 12:00 pm EDT. During this time users will not be able to register, login, or submit content.

FITTING WATER WITH AN EULER SERIES

Please use this identifier to cite or link to this item: http://hdl.handle.net/1811/20213

Show full item record

Files Size Format View
2001-TC-09.jpg 148.3Kb JPEG image Thumbnail of FITTING WATER WITH AN EULER SERIES

Title: FITTING WATER WITH AN EULER SERIES
Creators: Pickett, H. M.; Pearson, J. C.
Issue Date: 2001
Abstract: We have refit the water spectra for the (000), (010), (020), (100), and (001) vibrational states using a new fitting procedure that is based on a technique developed by Euler. The goal of this work is to fit the microwave and infrared line position data to the accuracy of the measurements. We have achieved satisfactory fits up to $J = 22$ for all states. The fit for (000) and (010) reproduces the data within experimental error. The triad data has some mutual inconsistencies, but we have obtained a satisfactory fit up to $J = 22$ and $K = 20$ with a mean fit error that is 10 times the estimated experimental error. Code for calculating the Euler series parameters are included in the SPFIT program set.
URI: http://hdl.handle.net/1811/20213
Other Identifiers: 2001-TC-09
Bookmark and Share