OSU Navigation Bar

The Ohio State University University Libraries Knowledge Bank

The Knowledge Bank is scheduled for regular maintenance on Sunday, April 20th, 8:00 am to 12:00 pm EDT. During this time users will not be able to register, login, or submit content.

THE APPLICATION OF A VUV-FT SPECTROMETER AND SYNCHROTRON RADIATION SOURCE TO MEASUREMENTS OF: I PREDISSOCIATED LINE WIDTHS OF THE SCHUMANN-RUNGE BANDS OF $O_{2}$

Please use this identifier to cite or link to this item: http://hdl.handle.net/1811/14088

Show simple item record

Files Size Format View
1997-TG-01.jpg 191.4Kb JPEG image Thumbnail of THE APPLICATION OF A VUV-FT SPECTROMETER AND SYNCHROTRON RADIATION SOURCE TO MEASUREMENTS OF: I PREDISSOCIATED LINE WIDTHS OF THE SCHUMANN-RUNGE BANDS OF $O_{2}$

dc.creator Yoshino, K. en_US
dc.creator Esmond, J. R. en_US
dc.creator Parkinson, W. H. en_US
dc.creator Thorne, A. P. en_US
dc.creator Murray, J. E. en_US
dc.creator Cox, G. en_US
dc.creator Learner, R. C. M. en_US
dc.creator Ito, K. en_US
dc.creator Matsui, T. en_US
dc.creator Imajo, Takashi en_US
dc.creator Cheung, A. S.- C. en_US
dc.creator Leung, K.- S. en_US
dc.date.accessioned 2006-06-15T15:47:45Z
dc.date.available 2006-06-15T15:47:45Z
dc.date.issued 1997 en_US
dc.identifier 1997-TG-01 en_US
dc.identifier.uri http://hdl.handle.net/1811/14088
dc.description Author Institution: Harvard Smithsonian Center for Astrophysics; Imperial College of Science, Technology and Medicine; Photon Factory, KEK; Kyushu University; University of Hong Kong en_US
dc.description.abstract The Imperial College VUV-FT spectrometer has been equipped with optically contacted, beam splitters made from single crystals of $MgF_{2}$ and the short wavelength performance has been demonstrated down to $\sim 139 nm$. To make ultrahigh resolution VUV photoabsorption cross section measurements with the VUV-FTS require a pure continuum source below 190 nm and the best choice: is synchrotron radiation from a storage ring facility. Moreover a suitable zero-dispersion predisperser is available on beam line 12-B of the synchrotron radiation source at the Photon Factory. We therefore moved the IC VUV FT spectrometer from Imperial College. London to the Photon Factory, Japan to exploit the bandwidth-limited synchrotron radiation as a background source for FT absorption spectroscopy. With resolution of 0.06 or $0.12 cm^{-1}$, we extended the linewidth measurements of the Schumann-Range (S-R) bands with $\nu_{12}$ in the wavelength range 181 to $175 nm$. The observed line widths consist of the instrumental, Doppler, and predissociation widths. The line profiles resulting from the convolution of the first two of these contributions are very closely Gaussian with widths of 0.12 and $0.15 cm^{-1}$ for spectra recorded with resolutions of 0.06 and $0.12 cm^{-1}$, respectively. The observed linewidths of the S-R bands with $\nu^{\prime}\geq 12$ will be presented. This work is partly supported by NSF Division of Atmospheric Sciences grant ATM-94-22854 to Harvard College Observatory, and by NASA Upper Atmospheric Research Program under Giant No. NAG5-484 to the Smithsonian Astrophysical Observatory. We also acknowledge the support of the UK Science and Engineering Research Council and the Paul Instrument Fund of the Royal Society for the development of the UV-FT spectrometer. en_US
dc.format.extent 196071 bytes
dc.format.mimetype image/jpeg
dc.language.iso English en_US
dc.title THE APPLICATION OF A VUV-FT SPECTROMETER AND SYNCHROTRON RADIATION SOURCE TO MEASUREMENTS OF: I PREDISSOCIATED LINE WIDTHS OF THE SCHUMANN-RUNGE BANDS OF $O_{2}$ en_US
dc.type article en_US